HomeProductsEnvironmental atmospheric monitoringUV DOAS Method GAS Analyzer – 3211H
  • 3211H UV DOAS Method GAS Analyzer
  • 3211H UV DOAS Method GAS Analyzer
  • 3211H UV DOAS Method GAS Analyzer
  • 3211H UV DOAS Method GAS Analyzer
  • 3211H UV DOAS Method GAS Analyzer
  • 3211H UV DOAS Method GAS Analyzer

UV DOAS Method GAS Analyzer – 3211H

The UV DOAS Method GAS Analyzer utilizes ultraviolet differential optical absorption spectroscopy (UV DOAS) technology to measure the concentration of SO₂, NO, NO₂, and NH₃ in flue gas, with optional measurement of gases such as O₂, CO, H₂S, and CO₂. It is unaffected by water vapor in the flue gas, offering high measurement accuracy and stability, making it particularly suitable for high-humidity and low-sulfur conditions. The UV DOAS module conducts measurements under hot and wet conditions, preventing the loss of flue gas components caused by water removal.

Features:
Smart Control, Fully Traceable
High-Precision Multi-Gas Measurement Capability, Auto-Ranging
Full-Process Heat Tracing, Exceptional Adaptability
Stable and Durable, Strong Anti-Interference Capability

Introduction

Parameters

Features

High-Precision Multi-Gas Measurement Capability, Auto-Ranging

  • Comes standard with the ability to measure SO₂, NO, NO₂, and NH₃ (UV DOAS), and features strong expandability with optional sensors for O₂, CO, CO₂ (NDIR), and H₂S.
  • Achieves automatic high/low range switching for SO₂, NO, NO₂, CO, and CO₂ to expand the measurement range.

Full-Process Heat Tracing, Exceptional Adaptability

  • The entire unit features full-process high-temperature heat tracing with no condensation points. Paired with titanium alloy vacuum insulation tubes, it effectively reduces heat loss and enhances on-site stability.
  • Adaptable to working condition measurement devices, it automatically imports working condition parameters and calculates data such as standard dry concentration and emission rates.

Smart Control, Fully Traceable

  • Built-in large-capacity memory supports instantaneous data storage and USB export. Paired with Bluetooth/wired dual printing modes, data output is flexible and efficient.
  • Supports one-click time synchronization via mobile phone; dynamic password management for administrators.
  • Features Beidou positioning, 4G remote data transmission, QR code printing, test spectrum printing, system logging, and more.

Stable and Durable, Strong Anti-Interference Capability

  • Based on in-depth research of the Ultraviolet Differential Optical Absorption Spectroscopy (UV DOAS) detection principle, it provides high-precision measurement of various harmful gases such as SO₂, NO, NO₂, and NH₃. It is free from water vapor interference and is suitable for on-site measurements under high-humidity and low-sulfur conditions.

Applications

Standards

  • GB 13223-2011: Emission standard of air pollutants for thermal power plants
  • GB/T 37186-2018: Gas analysis – Determination of sulfur dioxide and nitrogen oxides – Ultraviolet differential optical absorption spectroscopy
  • HJ 973-2018: Stationary source emission – Determination of carbon monoxide – Fixed potential electrolysis method
  • HJ 1045-2019: Technical requirements and detection methods of portable ultraviolet absorption measurement instruments for stationary source emission (sulfur dioxide and nitrogen oxides)
  • HJ 1131-2020: Stationary source emission – Determination of sulfur dioxide – Portable ultraviolet absorption method
  • HJ 1132-2020: Stationary source emission – Determination of nitrogen oxides – Portable ultraviolet absorption method
  • HJ/T 397-2007: Technical specifications for emission monitoring of stationary source
  • HJ 870-2017: Stationary source emission – Determination of carbon dioxide – Non-dispersive infrared absorption method
  • JJG 968-2002: Verification regulation of flue gas analyzers
  • JJF 1362-2012: Program of pattern evaluation of flue gas analyzers
  • DB37/T 2704-2015: Stationary source emission – Determination of nitrogen oxides – Ultraviolet absorption method
  • DB37/T 2705-2015: Stationary source emission – Determination of sulfur dioxide – Ultraviolet absorption method
  • DB37/T 2641-2015: Technical requirements and test methods for portable ultraviolet absorption multi-gas measurement systems
  • Q/0214 ZRB009-2017: Comprehensive flue gas analyzer
Host parameters
Parameter Range Resolution Error
Flue gas temperature (0~200)°C 1°C ±3.0°C
Flue gas static pressure (-30~30)kPa 0.01kPa ±2.0%FS
Flue gas dynamic pressure (0~2000)kPa 0.01kPa ±2.0%FS
Moisture content (0~40)VOL% 0.01VOL% ±2.0%
Sampling flowrate ≥0.5L/min 0.1L/min ±2.5%
Total pressure (60~130)kPa 0.01kPa ±0.5kPa
Excess air coefficient 1~99.99 0.01 ±2.5%
Working temperature (-20~50)°C
Load capacity of sampling pump ≥40kPa
Data storage >1000000 groups
Power Supply AC220V±10%,50Hz
Size (length 1270×width 120×height 248)mm
Weight About 5.5kg(battery include)
Power consumption <120W
 
 
Flue gas sampling parameters
Parameter Range Resolution Error
SO2 Low range: (0~430)mg/m3
High range: (0~5720)mg/m3
0.1 mg/m3 Relative error: ±3%
Repeatability: ≤1.5%
Response time: ≤90s
Stability: Indication change within 1h < 5%
Detection limit:
NO Low range: (0~200)mg/m3
High range: (0~1340)mg/m3
0.1 mg/m3
NO2 Low range: (0~300)mg/m3
High range: (0~1000)mg/m3
0.1 mg/m3 SO2 ≤ 2mg/m3
NO ≤ 1mg/m3
NO2 ≤ 2mg/m3
NH3 (0~300)mg/m3 0.1 mg/m3