HomeProductsEnvironmental atmospheric monitoringEnvironment Air Semi-Volatile Organic Compound (SVOC) Sampler
  • Environment Air Semi-Volatile Organic Compound (SVOC) Sampler
  • Environment Air Semi-Volatile Organic Compound (SVOC) Sampler

Environment Air Semi-Volatile Organic Compound (SVOC) Sampler

The 3925 Ambient Air SVOC Sampler is specifically designed for collecting air fluorides, heavy metals, and SVOCs, while also capable of collecting atmospheric particulate matter (TSP, PM10, PM2.5). It is suitable for routine aerosol monitoring in departments such as environmental protection, health, labor, work safety, scientific research, and education.

Features:
Flexible Sampling Modes
Stable, Durable, and Superior Sampling Performance
Powerful Expansion Capabilities
Exceptional Adaptability, Worry-Free in Harsh Environments

Introduction

The ambient air semi-volatile organic compound (SVOC) sampler is specifically designed for collecting air fluorides, heavy metals, and SVOCs. It can simultaneously collect atmospheric particulate matter (TSP, PM10, PM2.5).

  • Special Substances: Ambient air semi-volatile organic compound (SVOC) detection
  • Multi-substance Collection: Polycyclic Aromatic Hydrocarbons (PAHs) + TSP, PM10, PM2.5

Technical

  • Excellent waterproof, dustproof, and anti-collision performance; operates normally in rain, snow, dust, and severe smog conditions.
  • Equipped with an imported sampling pump controller featuring gas path blockage and low-flow protection functions.
  • Automatic data protection during power outages; automatically resumes sampling when power is restored.
  • Features a color touchscreen for more intuitive content display and easier operation.
  • Supports data document export.
  • Utilizes a high-precision, corrosion-resistant, and high-humidity-resistant electronic flow meter, ensuring high reliability and highly accurate sampling volumes.
  • Automatically measures atmospheric pressure and temperature, and automatically calculates standard condition volume.
  • Supports timed sampling, interval sampling, and continuous sampling.
  • Compatible with a variety of sampling heads to meet diverse sampling needs.

Features

Powerful Expansion Capabilities

  • Expandable for QR code printing of sampling data.
  • Expandable with a Beidou positioning module for automatic time synchronization using Beidou time.
  • Expandable with a 4G module to obtain network time and enable remote data transmission.
  • Expandable system log function to automatically record relevant changes and operations affecting instrument monitoring results.

Exceptional Adaptability, Worry-Free in Harsh Environments

  • Excellent waterproof, dustproof, and anti-collision performance; operates normally in rain, snow, dust, and severe smog conditions.

Multi-Purpose

  • Meets sampling requirements for glass fiber filters, PUF/adsorption resin VOC sampling canisters (VOCs); cellulose acetate nitrate membranes (fluorides); perchlorovinyl membranes (heavy metals), PTFE (polytetrafluoroethylene), and quartz filters.
  • By equipping different sampling heads, it can achieve the collection of TSP/PM10/PM2.5/fluorides/airborne heavy metals/SVOC/SVOCs.

Flexible Sampling Modes

  • Supports timed sampling, interval sampling, and 24-hour continuous sampling.

Stable, Durable, and Superior Sampling Performance

  • Utilizes an imported high-flow, high-negative-pressure, long-life (continuous operation >20,000 hours) brushless sampling pump. At a flow rate of 50 L/min, the load capacity exceeds 20 kPa.
  • Utilizes a high-precision, corrosion-resistant, and high-humidity-resistant electronic flow meter, ensuring high reliability and highly accurate sampling volumes.

Configuration

Reference Standards

HJ 93-2013 Technical requirements and test methods for ambient air particulate matter (PM10 and PM2.5) samplers

HJ 618-2011 Determination of atmospheric respirable particulate matter PM10 and PM2.5 in ambient air – Gravimetric method

HJ 646-2013 Ambient air and waste gas – Determination of gas and particle-phase polycyclic aromatic hydrocarbons – Gas chromatography/mass spectrometry

HJ 656-2013 Technical specification for manual monitoring method of ambient air particulate matter (PM2.5) – Gravimetric method

HJ 657-2013 Air and exhaust gas – Determination of lead and other metal elements in particulate matter – Inductively coupled plasma mass spectrometry

HJ 691-2014 Ambient air – Technical guideline for the sampling of semi-volatile organic compounds

HJ 868-2017 Ambient air – Determination of phthalate esters – High performance liquid chromatography

HJ 900-2017 Ambient air – Determination of organochlorine pesticides – Gas chromatography-mass spectrometry

HJ 902-2017 Ambient air – Determination of polychlorinated biphenyls – Gas chromatography-mass spectrometry

HJ 955-2018 Ambient air – Determination of fluorides – Filter sampling/fluoride ion-selective electrode method

HJ/T 374-2007 Technical requirement and test procedures for total suspended particulates sampler

JJG 943-2011 Verification Regulation of Total Suspended Particulates Samplers